Home/Products/PA systems
PA System

Replacing PA66 with PA6, and other nylon problems

Every time PA66 prices move, this question returns. The answer is not yes or no — it is under which conditions.

30% glass-fibre PA6 against PA66

PropertyPA6 + 0.3–0.4%Verdict
Tensile strength185 MPaMeets or exceeds
Flexural modulus9100 MPaMeets or exceeds
Notched Izod impact19.7 kJ/m²Meets or exceeds
Heat distortion temperatureBelow PA66Not met

Third-party test report. HDT is an intrinsic difference between PA6 and PA66 and cannot be fully closed by additives.

Where it can be used

  • Yes — cable ties, electrical switches, connectors, some automotive structural parts
  • With caution — continuous service above 120 °C, or reflow-soldered assemblies
  • No — parts where HDT is an acceptance criterion

The other route: PA6 reinforcing masterbatch

A major nylon producer built a PA6 reinforcing masterbatch on our additive. Added at 20% to PA6, it reaches tensile strength above 70 MPa and notched impact above 6.0 kJ/m², injection mouldable directly as a masterbatch. It has partially replaced PA66 in cable-tie compounds.

Additional benefit in glass-fibre systems

Intra-molecular lubrication improves fibre wet-out. In 35% glass-fibre PP, modulus and impact both rise while flow improves and processing temperature falls. The same mechanism applies in glass-fibre PA.

PA and mildew

At 1.5–3.0% of our targeted antimicrobial masterbatch, PA fibre fabrics and nonwoven reach Grade 0 mildew and fungal resistance, with no effect on spinning.

Test it before you price it

Tell us your resin grade, processing temperature, part thickness and the property you need to improve. We recommend a grade and dosage, ship 1–5 kg, and follow up with comparative data.

Or call Mr. Luo +86 135 5407 7117 +86 130 0101 5295

Request a sample