How Grade 0 mildew resistance is achieved

Many assume a poor rating means too little additive. In practice, adding more often makes it worse.

What Grade 0 means

Mildew testing grades samples by fungal growth on the surface. Grade 0 means no hyphal growth visible even under microscopy — the highest rating. Grade 1 means invisible to the eye but visible under magnification, and so on.

To reach Grade 0, a mixed mould spore population must be suppressed continuously for the full test period, typically 28 days. That demands persistence, not toxicity.

Why "add more" does not work

Three reasons:

  • Heat — most organic biocides begin decomposing between 200 and 230 °C, exactly the processing window, and spinning is hotter. Adding more means more decomposition, and the residue may cause odour and VOC.
  • Dispersion — if the biocide agglomerates, local concentration is excessive (creating defects) while other regions are under-dosed. Total loading looks adequate; effective surface area is not.
  • Migration — some biocides migrate to the surface and are lost, working early and failing later. Over a 28-day test the grade drops.

Our three responses

1. Stability above 250 °C

The decomposition onset is above 250 °C, covering conventional processing for PP, PE, PA and PVC and most spinning processes. Combined with no odour, low VOC and no toxicity, that is the precondition for fibre and food-contact work.

2. Dispersion completed during manufacture

Rather than dispersing inside the polymer, we form a micro-nano dispersion during masterbatch production. What enters the melt is already separated and does not re-agglomerate.

3. Controlled release from a composite carrier

The active is held in a composite carrier and released progressively rather than exposed all at once. That avoids local over-concentration and extends the effective period.

Measured result

At 1.5–3.0% in PA6 and PA66, PA fibre fabrics and nonwoven reach Grade 0 mildew and fungal resistance with no effect on spinning, and comply with FDA food-contact requirements.

To be precise: complies with requirements, not "FDA certified", which is a registration procedure for specific products and facilities.

Practical notes

  • Fibre customers must state spinning temperature; above 280 °C requires dedicated thermal validation
  • For white and light-coloured parts, check colour shift by trial first
  • Mildew resistance is a surface phenomenon; surface roughness and coatings affect real performance
  • For continuous immersion or high humidity, validate under actual conditions rather than relying on the standard test alone