Many assume a poor rating means too little additive. In practice, adding more often makes it worse.
Mildew testing grades samples by fungal growth on the surface. Grade 0 means no hyphal growth visible even under microscopy — the highest rating. Grade 1 means invisible to the eye but visible under magnification, and so on.
To reach Grade 0, a mixed mould spore population must be suppressed continuously for the full test period, typically 28 days. That demands persistence, not toxicity.
Three reasons:
The decomposition onset is above 250 °C, covering conventional processing for PP, PE, PA and PVC and most spinning processes. Combined with no odour, low VOC and no toxicity, that is the precondition for fibre and food-contact work.
Rather than dispersing inside the polymer, we form a micro-nano dispersion during masterbatch production. What enters the melt is already separated and does not re-agglomerate.
The active is held in a composite carrier and released progressively rather than exposed all at once. That avoids local over-concentration and extends the effective period.
At 1.5–3.0% in PA6 and PA66, PA fibre fabrics and nonwoven reach Grade 0 mildew and fungal resistance with no effect on spinning, and comply with FDA food-contact requirements.
To be precise: complies with requirements, not "FDA certified", which is a registration procedure for specific products and facilities.
Tell us your resin grade, processing temperature, part thickness and the property you need to improve. We recommend a grade and dosage, ship 1–5 kg, and follow up with comparative data.
Or call Mr. Luo +86 135 5407 7117 +86 130 0101 5295